Product Description:
The SoftStarterPro TG200 is an intelligent three-phase SCR power controller built for industrial heating applications that need closed-loop precision, not just simple open-loop power adjustment.
Key Features:
- Six Control Modes: Constant voltage, constant current, constant power, open loop, weekly zero-crossing, constant-period zero-crossing
- Adjustable PID Control: Proportional, integral, differential coefficients, keypad configurable
- Signal Input: 4-20mA, 0-5V, 0-10V, PWM (1-10kHz, 5-24V) — for external temperature controller/PLC integration
- RS485 Communication: Modbus RTU for remote monitoring and control
- LCD Display: Switchable readout of current, voltage, output percentage
- Six-Way Protection: Phase loss, thyristor breakdown, overcurrent, load disconnection, overheating, three-phase imbalance
- Fault Record: Stored fault history, viewable/clearable via keypad
General Technical Parameters:
| Parameter |
Value |
| Control Modes |
Constant voltage / constant current / constant power / open loop / weekly zero-crossing / constant-period zero-crossing |
| PID Parameters |
Proportional, integral, differential coefficients (keypad adjustable) |
| Signal Input |
4-20mA, 0-5Vdc, 0-10Vdc, PWM (1-10kHz, 5-24V) |
| Communication |
RS485, Modbus RTU |
| Protection Functions |
Phase loss, thyristor breakdown, load overcurrent, load disconnection, radiator overheating, three-phase current imbalance |
| Display |
LCD, switchable current/voltage/output percentage |
| Control Method |
Terminal control, keypad control, communication control, or keypad + communication |
| Rated Capacity (Model Designation) |
50KW / 75A |
| Recommended Load (Resistive, with 1.3× safety margin) |
≈38.5KW / ≈57.7A — do not exceed this value in continuous operation |
| Enclosure Protection |
IP20 |
| Operating Temperature |
-10~+60°C |
| Warranty |
18 months |
Application:
- Industrial Furnace and Kiln Temperature Control
- Large-Scale Heating and Thermal Processing Systems
- Manufacturing Process Heating Lines
- Applications Requiring Closed-Loop Power Stability
Note:
- Ratings are based on 380V three-phase input. For 220V, 440V, or 690V, contact us for a custom configuration — power, current, and recommended load values will differ.
- Do not connect capacitors to the output (U/V/W) terminals.
- Cut off input power before servicing. Both the upper and lower terminals remain energized when the input side is live.