Specification
  • Model: RQ6000-400KW
  • Current: 800A
  • Voltage: AC380V±15%
  • Dimension: 540*480*270MM
  • Gross Weight: 35KG
📄 Technical Support & Downloads

Product Description

The RQ6000-400KW is an online high-power motor controller for 380V three-phase induction motors, rated 800A. Built on power electronics and microprocessor control with SCR-based smooth acceleration, it delivers advanced control and protection for heavy-duty industrial applications, replacing star-delta and auto-transformer starters with no external bypass contactor required.

Key Features

  • 3 start modes: Current-limit / Voltage-ramp / Kick-start ramp for high-torque loads
  • 2 stop modes: Free stop / Soft stop (prevents water hammer)
  • Real-time 3-phase current display with independent calibration
  • Bilingual LCD (Chinese/English), stores last 12 fault records
  • Dual programmable relay outputs + 4-20mA analog output + RS485 Modbus RTU (standard)
  • No external bypass contactor needed, simplest wiring among all soft starter types

Applications

  • Heavy-Duty Industrial Motors, robust control for demanding high-power applications
  • Compressors, controlled acceleration protects valves and reduces pressure spikes
  • Conveyors, gentle load engagement, less mechanical shock on belts and gearboxes
  • Pumps & Fans, smooth start reduces water hammer and belt/duct stress

Technical Parameters

Parameter Specification
Model RQ6000-400KW
Rated Power / Current 400kW (535HP) / 800A
Input Voltage AC380V ±15%, 50/60Hz
Applicable Motor Squirrel-cage induction motor
Enclosure Steel enclosure
Start Modes Current-limit (50–600% adj.) / Voltage-ramp / Kick-start ramp
Stop Modes Free stop / Soft stop
Protection Rating IP00 (requires cabinet or indoor installation)
Cooling Forced air (dual fan)
Communication RS485 Modbus RTU (standard)
Analog Output 4–20mA
Protections Phase loss, overload, overcurrent, over/under-voltage, 3-phase imbalance, underload, start timeout
Ambient Temp / Altitude -25°C~+40°C / ≤2000m
Starting Frequency ≤15 starts/hour