Bypass Soft Starter RQ900 7.5KW 10HP 15A 380V 400V 420V

$348.58 USD
Shipping fees will be calculated at checkout.
Voltage
Quantity
Correct Model Selection for Your Project
Project & Ordering FAQs
Specification
  • Model: RQ900-7.5KW
  • Current: 11A-30A (varies by voltage, see table below)
  • Voltage: 380V/400V/420V/440V/480V/660V/690V
  • Dimension: 272*146*160MM
  • Gross Weight: 4KG
📄 Technical Support & Downloads

Product Description

The RQ900-7.5KW is a bypass-type soft starter for three-phase induction motors, available in 220V/380V/400V/420V/440V/480V/660V/690V configurations (15A at 380V/400V/420V). Built on power electronics and microprocessor control with SCR-based phase control, it limits inrush current to 2-4x rated current during startup, then switches to a bypass contactor for efficient, low-heat continuous running, requiring no cooling fan. An external bypass contactor is required for installation.

Key Features

  • 3 start modes: Current-limit / Voltage-ramp / Kick-start ramp
  • 2 stop modes: Free stop / Soft stop (prevents water hammer)
  • Bypass operation after startup, no cooling fan required, lower heat and energy loss during continuous run
  • Real-time 3-phase current display with independent calibration
  • Bilingual LCD (Chinese/English), stores last 12 fault records
  • Dual programmable relay outputs + dedicated bypass relay output + 4-20mA analog output + RS485 Modbus RTU (standard)
  • Requires external bypass contactor (sized to match motor rated current)

Applications

  • Pumps & Fans, soft-stop mode prevents water hammer, bypass operation reduces running heat for continuous duty
  • Conveyors, gentle load engagement, less mechanical shock on belts and gearboxes
  • Compressors, controlled acceleration protects valves and reduces pressure spikes
  • Crushers & Mixers, handles high starting torque loads with kick-start ramp mode

Technical Parameters

Parameter Specification
Model RQ900-7.5KW
Rated Power 7.5kW (10HP)
Applicable Motor Squirrel-cage induction motor
Start Modes Current-limit (50–600% adj.) / Voltage-ramp / Kick-start ramp
Stop Modes Free stop / Soft stop
Bypass Contactor External, required (not included)
Cooling Natural air cooling (no fan, bypass-type)
Protection Rating IP20
Communication RS485 Modbus RTU (standard)
Analog Output 4–20mA
Protections Phase loss, overload, overcurrent, over/under-voltage, 3-phase imbalance, underload, start timeout
Ambient Temp / Altitude -25°C~+40°C / ≤2000m
Starting Frequency ≤15 starts/hour
 

Voltage / Current Options

Voltage Rated Current
220V/240V 30A
380V/400V/420V 15A
440V/460V 15A
480V/500V 13A
660V 11A
690V 11A

Selection Tip

Recommended soft starter power = Motor Power × Load Factor (Pump/Fan: 1.2, Conveyor: 1.3, Compressor: 1.5, Crusher/Mixer: 1.6). Not sure which factor applies? Use our Soft Starter Selection Calculator: https://www.softstarterpro.com/blogs/selection-tools/soft-starter-selection-guide